نقد و بررسی تخصصی کليد هوایی اشنایدر الکتریک 1600 آمپر سه پل کشویی سری NT قدرت قطع 42kA
کليد هوایی اشنایدر الکتریک 1600 آمپر سه پل کشویی سری NT قدرت قطع 42kA
circuit breaker Masterpact NT16H1 – 1600 A – 3 poles – drawout – w/o trip unit
کليد هوایی اشنایدر الکتریک 1600 آمپر سه پل کشویی سری NT قدرت قطع 42kA
47240 –کليد هوایی 1600 آمپر سه پل کشویی سری NT قدرت قطع 42kA
NT16H13P2EF –میکرولوجیک 2
circuit breaker Masterpact NT16H1 – 1600 A – 3 poles – drawout – w/o trip unit
range of product |
Masterpact NT
|
|
---|---|---|
product or component type |
Basic frame
|
|
device short name |
Masterpact NT16
|
|
circuit breaker name |
Masterpact NT16H1
|
|
poles description |
3P
|
|
network type |
AC
|
|
breaking capacity code |
H1
|
|
suitability for isolation |
Yes conforming to IEC 60947-2
|
|
utilisation category |
Category B
|
network frequency |
50/60 Hz
|
|
---|---|---|
control type |
Push-button
|
|
mounting mode |
Drawout
|
|
[In] rated current |
1600 A at 40 °C
|
|
[Ui] rated insulation voltage |
1000 V AC 50/60 Hz conforming to IEC 60947-2
|
|
[Uimp] rated impulse withstand voltage |
12 kV conforming to IEC 60947-2
|
|
[Icm] rated short-circuit making capacity |
88 kA 220/415 V AC at 50/60 Hz
88 kA 440 V AC at 50/60 Hz 88 kA 525 V AC at 50/60 Hz 88 kA 690 V AC at 50/60 Hz |
|
[Ue] rated operational voltage |
690 V AC 50/60 Hz conforming to IEC 60947-2
|
|
circuit breaker CT rating |
1600 A
|
|
breaking capacity |
42 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
42 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 220…240 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 380…415 V AC 50/60 Hz conforming to IEC 60947-2 |
|
[Ics] rated service breaking capacity |
42 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
42 kA at 220/415 V AC 50/60 Hz conforming to IEC 60947-2 42 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 42 kA at 690 V AC 50/60 Hz conforming to IEC 60947-2 |
|
protection type |
Without protection
|
|
mechanical durability |
12500 cycles without maintenance conforming to IEC 60947-2
|
|
electrical durability |
3000 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
6000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 AC-23A: 3000 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 AC-23A: 6000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 AC-3: 6000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 |
|
connection pitch |
70 mm
|
|
[Icw] rated short-time withstand current |
24 kA 3 s conforming to IEC 60947-2
42 kA 0.5 s conforming to IEC 60947-2 42 kA 1 s conforming to IEC 60947-2 |
|
maximum breaking time |
25 ms
|
|
maximum closing response time |
50 ms
|
|
height |
322 mm
|
|
width |
288 mm
|
|
depth |
276.5 mm
|
standards |
IEC 60947-2
|
|
---|---|---|
product certifications |
LCIE
ASEFA |
|
pollution degree |
3 conforming to IEC 60664-1
|
|
ambient air temperature for operation |
-25…70 °C
|
|
ambient air temperature for storage |
-40…85 °C
|
Sustainable offer status |
Green Premium product
|
|
---|---|---|
EU RoHS Directive |
Compliant
EU RoHS Declaration |
|
Mercury free |
Yes
|
|
RoHS exemption information |
Yes
|
|
China RoHS Regulation |
China RoHS declaration
Product out of China RoHS scope. Substance declaration for your information |
|
Environmental Disclosure |
Product Environmental Profile
|
|
Circularity Profile |
End of Life Information
|
Warranty |
18 months
|
---|